Contact Us
The latest company news and electrical products from E Preston Electrical

Browse By Category

Browse By Date

E. Preston Electrical

Company News

Shurter Type 4710 - IEC Outlet with IDC Terminals Speed Assembly for Power Distribution Units

January 12, 2016

Schurter Logo1.jpg

Schurter announces its latest IEC appliance outlet with insulation displacement contact (IDC) terminals, the 4710. The new outlet provides increased power ratings over the popular 6610 series for heavier duty PDU applications.

4710The 4710 is a J style outlet according to IEC 60320, rated 20 A @ 250 VAC by UL/CSA and 16 A @ 250 VAC by ENEC. The lower current version, 6610 series, is a style F outlet, rated 15 A @ 250 VAC and 10 A @ 250 VAC respectively. The 4710 provides IDC terminals for 10 AWG / 6.0 mm2 in addition to 12 AWG / 4.0 mm2, which is the standard wire size for the 6610. The new wire option allows for larger diameter wire for the 4710's increased power capabilities. The Snap-in outlets fit panels with a thickness between 0.8 mm and 3 mm.

The 4710 and 6610 outlets are qualified for use in applications designed to IEC/EN 60950. Ideal for use in power distribution units, and other equipment where multiple outlets are banked in series, these IDC outlets allow wires to be bussed across the terminals, thereby connecting common terminals all at once and significantly reducing labor costs. The IDC terminals are arranged either along or across the connector pin axis for a horizontal or vertical mounting orientation. Wires are pressed into place with the protective back cover or with a tool. Versions with combination IDC and a quick-connect or solder terminal, for separate wiring of the line connection, are also available.

The outlets are offered with light pipe options for status indication. They also mate with V-Lock latching cordsets designed to prevent unintentional disconnection from the power. Approvals include cURus, ENEC and CCC.

Technical Data:

*  Standards: IEC 60320-1, UL 60320-1, CSA C22.2 no. 60320-1-11
*  Approvals: ENEC, UL, CSA
*  Nominal ratings IEC/CCC: 16 A / 250 VAC, 50 Hz
*  Nominal ratings UL/CSA: 20 A / 250 VAC, 60 Hz
*  Permissible operating temperature: –25 °C to 70 °C
*  For solid wires with cross-sections 10 AWG / 6.0 mm2, 12 AWG / 4.0 mm2 and 2.5 mm2

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

 

 

For more information
We are happy to help!

Bulgin Announces New 4000 Series

November 25, 2015

Bulgin has expanded its ever-popular Buccaneer® range of environmentally-sealed power and data connectors with the introduction of the new Buccaneer 4000 Series. Building on the success of the Buccaneer 6000 and 7000 Series of quick locking connectors, this latest offering provides the same twist lock coupling and ‘fit and forget’ connectivity in a more compact format, making it easier for product engineers to integrate into their system designs.

4000 Series

The Buccaneer 4000 Series has been developed to provide excellent sealing characteristics to IP66, IP68 and IP69K standards – ensuring true environmental protection in harsh conditions – as well as to withstand vibrations, shocks and corrosion to EN/IEC 60068 requirements. Each unit has a UV-resistant, UL94-V0 flammability-rated plastic body equipped with a simple and efficient twist locking mechanism, allowing a secure connection without the need for specialist tools. Currently available in 3, 8 and 12 pole configurations rated up to 13A, 600V – plus a micro-B USB data connector – it offers a choice of solder and crimp contacts, and can accommodate cables from 3 to 7 mm in diameter. Together with a choice of in-line or panel mounting options, this makes the Buccaneer 4000 Series ideally suited to a wide range of marine, industrial, transport and infrastructure applications, especially where space is at a premium.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Schurter Type 5707 with IP 54 Protected V-Lock Cord Set

July 23, 2015

Schurter Logo1.jpg

5707 VLock

Schurter is pleased to announce, that its power entry module, series 5707, now offers IP 54 protection with V-Lock cord sets at the power input, in addition to IP 65 protection to the equip-ment. The sealed module is ideal for use in medical equipment exposed to leaks, drips and spills, as well as equipment subject to routine washing.

The compact module combines an appliance inlet, fuseholder, and standard or medical EMC filter rated up to 8 A at 250 VAC. The original 5707 offers IP 65 seal protection at the panel opening, around the fuseholders, and between the inlet and connector pins. The module can also be fitted with an additional gasket in the inlet cavity for IP 54 protection between the inlet and the cord connector. A V-Lock cord set prevents unintentional disconnection.

The 5707 is cURus and ENEC approved. The appliance inlet complies with IEC/EN 60320-1; Fusehold-ers are shock-safe according to IEC/EN 60127-6, PC2. The module offers pre-wired electrical connec-tions, using 6.3x0.8 quick connect terminals. Variations include: Class I, C14, or Class II, C18 appliance inlet; 1- or 2- pole fuseholders; front or rear mount mounting; capacitors class X1 and Y1 for increased voltage withstand; black or white plastic socket.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Schurter Appliance Outlet 6610 Series with Integrated Light Pipe

July 7, 2015

Schurter Logo1.jpg

6610 light pipe

Schurter's 6610 series appliance outlet according to IEC 60320-2-2, Style F, is now available with an integrated light pipe. The fiberglass light pipe indicates operational status, or other function status, as an optional feature to standard connectors. It is designed to channel light from LEDs on the pc board to the front of the connector.

The new technology offers flexible design options including the number of light pipes, 1-4, as well as options for light pipe lengths and diameters. The flexibility of design allows for efficient customer-specific solutions, while enabling increased
opportunity to signal status information from the power grid to the user.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

New Bulgin Buccaneer 6000 and 7000 Series - Solder Contacts Now Available

June 18, 2015

Buccaneer Solder Contacts

Offering greater flexibility within the popular 6000 & 7000 series range, Bulgin is happy to announce Solder Contacts options are now available in addition to our Crimp Contacts.

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Schurter Type KFA Compact Power Entry Module now with Ground Line Choke

March 5, 2015

Schurter Logo1.jpg

Schurter's popular power entry module, KFA series, is now equipped with an additional ground line choke to suppress high frequency interference arising from ground loops on the ground line. In addition, the newly added ground line choke improves asymmetric attenuation in higher frequencies in medical filter versions. The KFA series with existing common-mode choke on the phase and neutral conductors, together with an additional ground line choke, is well enhanced to address the growing EMC challenges facing compliance engineers today.

KFA

Ground loops arise through different impedances of different ground line connections in one or multiple pieces of equipment. While all ground connections have the same potential level for the 50 Hz load current, these can have different potential levels for high-frequency interference. The ground line choke,  which is wired between the power-inlet connector and the filter output, smartly addresses this phenomenon. Because of its placement directly at the power line input, high-frequency interference currents on the ground line are prevented from bypassing the filter through the equipment housing. The ground line choke isolates the equipment chassis against high frequencies and the equipment ground from the ground on the line power connection. This approach effectively breaks any possible ground loops.

Audio equipment for instance is known for being prone to ground loop problems. Often referred to as hum or buzz, the KFA, with ground line choke, is well suited for suppressing interferences that lead to diminished sound quality. The KFA is also well suited for medical equipment required to use low leakage
filters for increased patient safety. The reduced Y capacitance to ground, or absence thereof, leads to reduced asymmetric attenuation in higher frequencies. The KFA with ground line choke helps to compensate for this reduced performance.

The KFA power entry module includes an IEC C14 power inlet connector with a 1- or 2-pole fuseholder and EMC filter and is available in a wide range of models and designs. The series offers current levels from 1A to 10A at 250 VAC according to IEC and UL standards. The series has ENEC and cURus approvals and is suited for applications according to IEC 60950. Special filter versions, M5 and M80, are available for medical devices according to IEC 60601-1. Wiring is done using quick-connect terminals or wire leads. The KFA is compatible with V-Lock cord sets, designed to safeguard against unintentional disconnection of the power.

Technical Data / Approvals / Prices
- IEC C14 power-inlet connector with 1/2-pole fuseholder and a filter
- Filter standard, medical M5 / M80 versions
- Rated currents: 1, 2, 4, 6, 10A (ENEC / UL / CSA) at 40°C
- Screw or snap-in assembly
- V-Lock plug-retention safeguard

Application
- For applications with noise on the ground wire
- For applications with ground loops
- Applications with high asymmetrical attenuation requirements
- Suited for medical equipment according to IEC 60601-1

.

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

 

For more information
We are happy to help!

Schurter DC12 Protection Class II Compact Power Entry Module for Protection Class II Equipment

February 16, 2015

Schurter Logo1.jpg

Schurter expands its wide range of power entry modules to include versions, without ground pin, for use in Protection Class II double-insulated applications. The DC12 power entry module is already popular for use in Protection Class I equipment, due to its high performance switch and EMC filter functions integrated into one compact package. The new Protection Class II version is perfectly suited for medical equipment used at home where the medical standard prescribes the use of Protection Class II design.

DC12_class

The new DC12 Class II version is according to IEC 60320-1, style C18. It is particularly well suited for use in medical equipment according to the IEC standard 60601-1-11, which outlines additional safety measures specific to medical equipment intended for use in the home. There is increasing demand for
such equipment as populations around the world age and healthcare costs continue to rise.

Protection Class II equipment, in contrast to Protection Class I equipment, generally has no metal case. This category of equipment is called double insulated, and requires higher safety levels for energized components relative to exposed surfaces. The DC12 Class II power entry module provides double
insulation between energized components and exposed parts. This reinforced insulation is tested with a voltage of 4000 VDC between the energized conductor (L) and the neutral conductor (N) relative to the filter case.

The DC12 line switch is available in 1- or 2-pole and touts high inrush current withstand capability. The EMC filter is available in medical and low leakage, M5, versions. This integrated filter at the power input provides highly effective interference suppression, which results in optimized electromagnetic
compatibility. Current ratings range from 1-10 A at 250 VAC. Versions with quick-connect or solder terminals are available. The DC12 is available in black or white. Mating V-Lock cord sets are available to safeguard against unintentional disconnection of the power. The DC12 Class I and Class II are ENEC and cURus approved. They are suited for use in equipment according to IEC 60950, IEC 60601-1, in addition to IEC 60601-1-11.

Technical Data / Approvals / Prices
- IEC C18 power-inlet connector with 2-pole switch and a filter
- M5 medical filter
- Rated currents: 1, 2, 4, 6, 10A (ENEC / UL / CSA) at 40°C
- Screw or snap-in assembly
- Optional V-Lock plug-retention safeguard
- Version in white available

Application
- For totally insulated equipment according to IEC 61140
- Suited for medical equipment according to IEC 60601-1
- Especially well suited for medical equipment intended for use in the home according to IEC 60601-1-11

.

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Schurter IEC Cord Connectors C21 and Appliance Inlet C22

January 15, 2015

Schurter Logo1.jpg

1658 - 1659 - 1681
Schurter IEC Cord Connectors C21 and Appliance Inlet C22
For Very Hot Conditions 155°C
IEC 16 A / UL/CSA 20 A

Series C21_C22

 

Schurter introduces its high temperature inlet and cord connectors series to extend its range of IEC high-temperature power inlets and outlets according to IEC. The high-temperature appliance inlets and cord connectors are designed according to IEC for 16 A at 250 VAC, and according to UL / CSA for 20 A at 250 VAC.

Series C21_C22 Pin temperature may reach a maximum of 155°C. Furthermore, the appliance inlets and cord connectors meet the requirements of IEC 60335-1 for household appliances, which covers enhanced requirements of glow wire tests for unattended household appliances according to IEC 60695-2-12 and -13. They have certifications from ENEC, UL/ CSA and CCC.

Series C21_ C22The high-temperature appliance inlet, series 1681, offers types for snap-in or screw-on mounting. The inlet can be specified with terminals for solder, quick-connect or screw connections. The cord connector comes in a straight, series 1658, and an angled, series 1659, design. Cables with a conductor cross-section of up to 2.5 mm2 or 10 AWG can be used.

The IEC high-temperature appliance inlet and the cord connectors are RoHS and CHINA-RoHS compliant. They are used in equipment that operates in elevated ambient temperatures and/or with high currents, such as datacom equipment, where increased power and decreased size are trending, as well as portable industrial equipment such as heating systems.

Applications
• Power Supplies
• IT / Telecom equipment
• Server / Data Storage
• Furnaces, Heating Equipment, Ovens
• Lighting systems

.

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Schurter KFA and DA22 Standard with Notch for V-Lock Cord Retaining

December 18, 2014

Schurter Logo1.jpg

KFA_V_Lock_Pressebild

Schurter is pleased to announce, that its compact KFA and DA22 Series power entry modules, with 1- or 2-pole fuseholder and filters, now mates with V-Lock cord sets. The KFA’s and DA22’s new V-Lock compatible feature prevents unintended disconnection of the power from the equipment.

Unlike wire bail or clamp accessories, no additional costly hardware is necessary to install the cord retaining system. The cordset safely latches into a notch in the plastic housing of the KFA and DA22. Removing the cordset is easily achieved by depressing the latch. V-Lock power cords are offered in a wide range of cord lengths and country-specific plugs, including NEMA 5-15 standard hospital grade versions.

The KFA and DA22 are ideal for use in medical devices, IT and audio equipment used on stage, where the power to the equipment must withstand mechanical stress on the cord. It features C14 inlet, 1- or 2-pole fuseholder for 5x20mm fuses, mains filter, 4.8 x 0.8mm quick-connect or PCB terminals, and screw-on or snap-in mounting. Optional voltage selector allows for use in international markets. Current rating 1 to 10 A at 250 VAC.

Approvals include UL, CSA, VDE and CCC.

Features and benefits:
- Power entry module with 3 functions: Appliance Inlet, Fuseholder and Line filter
- Suitable for use in medical equipment according to IEC/UL 60601-1
- Optional fuse drawer "extra-safe" according to IEC/UL 60601-1
- V-Lock retaining system for mating cordsets
- No additional components required for cord retentionFeatures and benefits:
- Power entry module with 3 functions: Appliance Inlet, Fuseholder and Line filter
- Suitable for use in medical equipment according to IEC/UL 60601-1
- Optional fuse drawer "extra-safe" according to IEC/UL 60601-1
- V-Lock retaining system for mating cordsets
- No additional components required for cord retention

.

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!

Hylec DEBOX - The Only In-Line Junction Box You May Ever Need

December 4, 2014

Hylec-APL launches its new DEBOX junction box. The virtually tool-less design facilitates installation faster than the leading competitor and offers greater flexibility. For use in internal applications in a variety of different industries, but especially in the lighting sector, it will reduce time on-site and in turn reduce the overall costs of installation.

DEBOX

The DEBOX features:
•   4 Pole, 24 amp, 4mm terminal block supplied as standard.
•   Can be used with screwless terminals, Kwik-Wire commoning terminals or IDC connectors
•   Can accommodate flat or round profile cables
•   Polypropylene UL 94 V2 material
•   Fixing pin clips the lid in place quickly and effectively
•   Two mounting ears for secure external fastening
•   Virtually tool-less assembly

 

Enquiry Form: https://www.epreston.co.uk/contact/

Home Page: https://www.epreston.co.uk/epblog/

For more information
We are happy to help!
1 14 15 16 24

Featured Products

Manufacturers

Privacy Policy
Website built and optimised by Miltec Digital

Get In Touch

Fill in your details to request a call from one of our sales representatives.
E Preston Contact Form
chevron-leftchevron-right linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram